{"product_id":"ndd-easy-on-pc-spirometer","title":"NDD Easy on-PC Spirometer","description":"\u003cspan class=\"c-text__label\"\u003eProduct overview\u003c\/span\u003e\n \u003cul class=\"c-text__list\"\u003e\n \u003cli\u003eFully integrated and PC-controlled\n\u003c\/li\u003e\n \u003cli\u003eNo calibration required\n\u003c\/li\u003e\n \u003cli\u003eImmediate quality feedback\n\u003c\/li\u003e\n \u003cli\u003eHigh shock and vibration resistance\n\u003c\/li\u003e\n \u003cli\u003eCompatible with EasyOne Connect software\u003c\/li\u003e\n \u003c\/ul\u003e \u003ch4\u003eNDD Easy on-PC Spirometer\u003c\/h4\u003e\n\n\u003cp\u003eThe fully integrated NDD Easy on-PC Spirometer delivers reliable results and high accuracy \u003cb\u003ewithout requiring calibration\u003c\/b\u003e, thanks to innovative TrueFlow™ technology. Workflow is accelerated thanks to instant \u003cb\u003equality assessment and interpretation\u003c\/b\u003e. Interactive displays, \u003cb\u003eengaging animations and real-time graphics\u003c\/b\u003e facilitate the performance of the pulmonary function test for both children and adults.\u003c\/p\u003e\u003cbr\u003e\n\u003cp\u003eThe proven \u003cb\u003eTrueFlow™ technology\u003c\/b\u003e is based on a unique ultrasonic technology that ensures \u003cb\u003eaccurate flow and volume measurements\u003c\/b\u003e throughout the life of the units. It enables \u003cb\u003econtact- and resistance-free measurement\u003c\/b\u003e and convinces with excellent accuracy and robustness.\u003c\/p\u003e\u003cbr\u003e\n\u003cp\u003eTo effectively \u003cb\u003eprotect the patient and staff from cross-contamination\u003c\/b\u003e, \u003cb\u003ehygienic disposable spirettes\u003c\/b\u003e from the manufacturer are used when performing spirometry. Not only is the risk of germ transmission reduced, but at the same time the reprocessing effort of the device is minimized, because the \u003cb\u003epenetration of liquids from the outside is not possible\u003c\/b\u003e and contamination of the sensor is also ruled out.\u003c\/p\u003e\u003cbr\u003e\n\u003cp\u003eIf required, NDD inline filters are also available, which provide\u003cb\u003e reliable \"double protection\"\u003c\/b\u003e against infections and pathogens such as SARS-CoV-2. These can be connected to the spirettes via the matching NDD filter adapters.\u003c\/p\u003e\u003cbr\u003e\n\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\tNDD Easy on-PC Spirometer \u003c\/li\u003e\n\u003cli\u003e\tFully integrated, PC-controlled spirometer \u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tReliable results with high accuracy thanks to TrueFlow™ technology\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tNo calibration required\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\tEasy implementation thanks to real-time diagrams and animations\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tImmediate quality feedback\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\tEMR\/EHR connection, supports HL7\/XML data exchange\u003c\/li\u003e\n\u003cli\u003e\tFlexible choice of settings\u003c\/li\u003e\n\u003cli\u003e\tPerfect for stationary and mobile use\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tHigh shock and vibration resistance\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\tRobust cable protection\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tFor use with the EasyOne Connect software platform\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tHigh infection protection when using the NDD inline filters\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\tConforms to the Medical Device Directive 93\/42\/EEC\u003c\/li\u003e\n\u003cli\u003e\tWith CE-marking\u003c\/li\u003e\n\u003cli\u003e\tIdeal for general practitioners, pneumologists, emergency doctors and hospitals\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\n\u003ch3\u003eEasyOne Connect Software Platform\u003c\/h3\u003e\n\u003cp\u003eBy connecting the NDD Easy on-PC Spirometer via USB to a work computer with EasyOne Connect software installed, a\u003cb\u003ell advanced spirometry features are available free of charge\u003c\/b\u003e. The software complies with \u003cb\u003eATS\/ERS Standards 2005 and 2019\u003c\/b\u003e.\u003c\/p\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\tTest quality and evaluation\u003c\/li\u003e\n\u003cli\u003e\tComments function\u003c\/li\u003e\n\u003cli\u003e\tChild-friendly animations\u003c\/li\u003e\n\u003cli\u003e\tCustom test reports \u0026amp; provocation protocols\u003c\/li\u003e\n\u003cli\u003e\tExtensive selection of reference values (%Pred, Z-Score and LLN)\u003c\/li\u003e\n\u003cli\u003e\tImport of external PFT results\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\n\n\n\n\n\n\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrint options: direct print control or via network\u003c\/li\u003e\n\u003cli\u003eData management: EasyOne Connect (SQLite, MS SQL Server)\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tInterface: HL7, XML, GDT\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e\tStorage capacity: \u0026gt; 10,000 tests\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\tPatient age: spirometry \u0026gt; 4 years\u003c\/li\u003e\n\u003cli\u003e\tDevice classification: Type BF applied part\u003c\/li\u003e\n\u003cli\u003e\tStandards: ISO 13485, ISO 14971, IEC 62366, IEC 62304, ISO 26782, ISO 23747, IEC 60601-1, IEC 60601-2, ISO 10993-1\u003c\/li\u003e\n\u003cli\u003e\tLanguages: German, Chinese, Danish, English, Finnish, French, Italian, Japanese, Croatian, Dutch, Norwegian, Portuguese, Russian, Spanish, Swedish, Turkish, Vietnamese\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\n\u003ch3\u003ePC\/Laptop Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHard disk capacity: installation\/system 1 GB; data up to 4 GB\u003c\/li\u003e\n\u003cli\u003e\tRAM: 2 GB\u003c\/li\u003e\n\u003cli\u003e\tOperating systems: Windows 7, Windows 8 and 8.1 (32 and 64 bit), Windows 10 (32 and 64 bit)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\n\n\u003ch3\u003eParameters\u003c\/h3\u003e\u003cdiv class=\"c-text__table\"\u003e\u003ctable class=\"table table-bordered\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFVC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eATI, BEV, EOTV, FEF10, FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50\/FVC, FEF50\/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5\/FVC, FEV.75, FEV.75\/FEV6, FEV.75\/FVC, FEV.75\/VCmax, FEV1, FEV1\/FEV6, FEV1\/FVC, FEV1\/FVC6, FEV1\/VC, FEV1\/VCmax, FEV3\/FVC, FEV3\/VCmax, FEV3, FEV6, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, t0, VC, VCmax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFVL\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eATI, BEV, EOTV, FEF10, FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50\/FVC, FEF50\/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5\/FVC, FEV.75, FEV.75\/FEV6, FEV.75\/FVC, FEV.75\/VCmax, FEV1, FEV1\/FEV6, FEV1\/FVCATI, BEV, CVI, E50\/150, EOTV, FEF10. FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50\/FVC, FEF50\/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5\/FVC, FEV.75, FEV.75\/FEV6, FEV.75\/FVC, FEV.75\/VCmax, FEV1, FEV1\/FEV6, FEV1\/FIV1, FEV1\/FIVC, FEV1 FVC, FEV1\/VC, FEV1\/VCmax, FEV3\/FVC, FEV3\/VCmax, FEV3, FEV6, FIF25, FIF2575, FIF50, FIF50\/FEF50, FIF75, FIV.25, FIV.5, FIV1, FIVC, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MIF25, MIF50, MIF75, MMEF, MMIF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, PIF, t0, VC, VCmax, FEV1\/FVC6, FEV1\/VC, FEV1\/VCmax, FEV3\/FVC, FEV3\/VCmax, FEV3, FEV6, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, t0, VC, VCmax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSVC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eERV, IC, IRV, Rf, VC, VCex, VCin, VCmax, VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMVV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMVV, MVV6, MVVtime, Rf, VCext, VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\n\u003ch3\u003eFlow Volume Sensor\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType: ultrasound runtime\u003c\/li\u003e\n\u003cli\u003e\tFlow range: ± 16 l\/s\u003c\/li\u003e\n\u003cli\u003e\tFlow resolution: 4 ml\/s\u003c\/li\u003e\n\u003cli\u003e\tFlow accuracy: ± 2 % or 0.020 l\/s\u003c\/li\u003e\n\u003cli\u003e\tVolume resolution: 1 ml\u003c\/li\u003e\n\u003cli\u003e\tVolume accuracy: ± 2 % or 0.050 l\u003c\/li\u003e\n\u003cli\u003e\tPEF accuracy: ± 5 % or 0.200 l\/s\u003c\/li\u003e\n\u003cli\u003e\tMVV accuracy: ± 5 % or 5 l\/min\u003c\/li\u003e\n\u003cli\u003e\tResistance: ~ 0.3 cm H2O\/l\/s at 16 l\/s\u003c\/li\u003e\n\u003cli\u003e\tMeasuring frequency: 400 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Orange Medical","offers":[{"title":"Default Title","offer_id":51895386734919,"sku":"141951","price":1546.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/6301\/9079\/files\/141436_detail_1_0a9b6c2f-633b-4d41-ab4f-cc16ca71ebdf.jpg?v=1752054316","url":"https:\/\/orangemedical.co.uk\/products\/ndd-easy-on-pc-spirometer","provider":"Orange Medical","version":"1.0","type":"link"}