{"product_id":"master-palm-2","title":"Master Palm 2","description":"\u003cspan class=\"c-text__label\"\u003eProduct overview\u003c\/span\u003e\n \u003cul class=\"c-text__list\"\u003e\n \u003cli\u003eAutomatic alignment of the HD screen\n\u003c\/li\u003e\n \u003cli\u003eTwo display modes allow customised settings\n\u003c\/li\u003e\n \u003cli\u003eMonitoring function with programmable alarm\n\u003c\/li\u003e\n \u003cli\u003ePlethysmography curve display\n\u003c\/li\u003e\n \u003cli\u003eLarge selection of interchangeable sensors\u003c\/li\u003e\n \u003c\/ul\u003e \u003ch4\u003eMaster Palm 2\u003c\/h4\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eMaster Palm 2\u003c\/strong\u003e from Spengler is a compact and high-performance \u003cstrong\u003epulse oximeter\u003c\/strong\u003e designed for precise measurement of \u003cstrong\u003eoxygen saturation (SpO₂)\u003c\/strong\u003e and \u003cstrong\u003epulse rate\u003c\/strong\u003e in adults, children and newborns. Ideal for hospitals, clinics and mobile care settings, it features \u003cstrong\u003eautomatic screen rotation\u003c\/strong\u003e, \u003cstrong\u003ecustomisable alarms \u003c\/strong\u003eand a \u003cstrong\u003ewide range of interchangeable sensors\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Spengler\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Master Palm 2 Pulse Oximeter\u003c\/li\u003e\n\t\u003cli\u003eCompact and reliable medical device for SpO₂ and pulse rate monitoring\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eHD screen with automatic orientation\u003c\/strong\u003e for easy readability\u003c\/li\u003e\n\t\u003cli\u003eDual display modes: numeric view and plethysmographic waveform\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm system\u003c\/strong\u003e for individual patient needs\u003c\/li\u003e\n\t\u003cli\u003eAdjustable volume, display settings, and system preferences\u003c\/li\u003e\n\t\u003cli\u003eAudible alarms can be muted for up to 120 seconds\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eReal-time plethysmography waveform display\u003c\/strong\u003e for enhanced diagnostics\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSupports a wide variety of compatible sensors\u003c\/strong\u003e for all age groups\u003c\/li\u003e\n\t\u003cli\u003eHigh-precision readings with clear and bright display\u003c\/li\u003e\n\t\u003cli\u003eIncludes data memory function for continuous monitoring\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eCan be used as a SpO₂ monitoring system\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eExtended battery life – ideal for long shifts or mobile use\u003c\/li\u003e\n\t\u003cli\u003e2-year manufacturer's warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eHigh-Accuracy SpO₂ Monitoring for All Ages\u003c\/h3\u003e\n\n\u003cp\u003eThe Spengler Master Palm 2 delivers \u003cstrong\u003eaccurate, fast, and consistent readings\u003c\/strong\u003e, making it an excellent tool for both \u003cstrong\u003eroutine check-ups\u003c\/strong\u003e and \u003cstrong\u003econtinuous vital signs monitoring\u003c\/strong\u003e. Whether used in emergency care, general wards or outpatient settings, this pulse oximeter ensures \u003cstrong\u003ediagnostic precision\u003c\/strong\u003e and ease of use.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eWith \u003cstrong\u003etwo intuitive display options\u003c\/strong\u003e and \u003cstrong\u003eautomatic screen adjustment\u003c\/strong\u003e, the device adapts seamlessly to any clinical situation. The \u003cstrong\u003eplethysmographic waveform\u003c\/strong\u003e enhances visual assessment of pulse activity, while the \u003cstrong\u003ecustomisable alarms\u003c\/strong\u003e ensure safe and efficient monitoring. Its compatibility with multiple sensor types adds flexibility for use across all patient demographics.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e2.4\" HD display with automatic screen rotation\u003c\/li\u003e\n\t\u003cli\u003ePersonalised alarm settings for patient-specific thresholds\u003c\/li\u003e\n\t\u003cli\u003eCustomisable user interface and system settings\u003c\/li\u003e\n\t\u003cli\u003eDetailed pulse curve via plethysmographic waveform\u003c\/li\u003e\n\t\u003cli\u003eRapid and precise SpO₂ and pulse rate measurements\u003c\/li\u003e\n\t\u003cli\u003eDual use: standalone pulse oximeter or SpO₂ monitoring system\u003c\/li\u003e\n\t\u003cli\u003eWide compatibility with paediatric, neonatal, and adult sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003cdiv class=\"c-text__table\"\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:750px\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2.4\" TFT screen; resolution: 320 x 240 pixels\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eDisplay Mode\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMode 1: Numeric and SpO₂\u003cbr\u003e\n\t\t\tMode 2: Pulse, plethysmographic curve, SpO₂ value and SpO₂ waveform\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eSpO₂\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRange: 0–100%\u003cbr\u003e\n\t\t\tResolution: 1%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eHeart Rate\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRange: 25–250 bpm\u003cbr\u003e\n\t\t\tResolution: 1 bpm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003ePulse Intensity\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eDisplayed as a bar graph\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRed: 660 nm\u003cbr\u003e\n\t\t\tInfrared: 905 nm\u003cbr\u003e\n\t\t\tPower: \u0026lt;15 nW\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3 x AA batteries (LR06)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026gt;14 hours of continuous use with SpO₂ enabled, screen at minimum brightness, alarms muted, at 25 °C ambient temperature\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTemperature: 5–40 °C\u003cbr\u003e\n\t\t\tHumidity: 15–85%\u003cbr\u003e\n\t\t\tAir pressure: 700–1060 hPa\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eStorage Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTemperature: -20 to +55 °C\u003cbr\u003e\n\t\t\tHumidity: 10–93%\u003cbr\u003e\n\t\t\tAir pressure: 500–1060 hPa\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e58.5 x 123 x 28 mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026lt;200 g (excluding batteries)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1x Spengler Master Palm 2 pulse oximeter\u003c\/li\u003e\n\t\u003cli\u003e1x SpO₂ sensor for adults\u003c\/li\u003e\n\t\u003cli\u003e3x AA batteries (type LR06)\u003c\/li\u003e\n\t\u003cli\u003e1x User manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eOrder Now\u003c\/h3\u003e\n\n\u003cp\u003eGet the Master Palm 2 today and enhance your clinical workflow with this advanced pulse oximeter – delivering \u003cstrong\u003eaccurate diagnostics\u003c\/strong\u003e, \u003cstrong\u003eversatile monitoring\u003c\/strong\u003e and \u003cstrong\u003ereliable patient care\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Orange Medical","offers":[{"title":"Default Title","offer_id":51897869861191,"sku":"150338","price":305.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/6301\/9079\/files\/150338-master-palm-2-spengler-frontal_5509f054-9ed1-42df-864f-2f6ea6ffa6d7.jpg?v=1752069319","url":"https:\/\/orangemedical.co.uk\/products\/master-palm-2","provider":"Orange Medical","version":"1.0","type":"link"}