{"product_id":"lumiradx-rapid-test-hba1c","title":"LumiraDX Rapid Test HbA1c","description":"\u003cspan class=\"c-text__label\"\u003eProduct overview\u003c\/span\u003e\n \u003cul class=\"c-text__list\"\u003e\n \u003cli\u003eFor use with the LumiraDX platform\n\u003c\/li\u003e\n \u003cli\u003eDelivers reliable results within minutes\n\u003c\/li\u003e\n \u003cli\u003eFast test performance with short hands-on time\n\u003c\/li\u003e\n \u003cli\u003eParticularly uncomplicated sample collection\n\u003c\/li\u003e\n \u003cli\u003eAvailable for CRP, INR, D-Dimer, HbA1c and NT-proBNP\u003c\/li\u003e\n \u003c\/ul\u003e \u003ch4\u003eLumiraDX Rapid Test\u003c\/h4\u003e\n\n\u003cp\u003eThe LumiraDX Rapid Tests from Roche Diagnostics are intended for use with the\u003cstrong\u003e LumiraDX platform\u003c\/strong\u003e, offering fast and \u003cstrong\u003ereliable diagnostics directly at the point of need\u003c\/strong\u003e. Thanks to the simple sample collection and \u003cstrong\u003eminimal hands-on time\u003c\/strong\u003e, the tests can be performed in just a few steps – helping healthcare professionals save valuable time during their daily routine.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAccurate results\u003c\/strong\u003e are available \u003cstrong\u003ewithin minutes\u003c\/strong\u003e, supporting well-founded clinical decision-making. The tests are available for various parameters such as \u003cstrong\u003eCRP, D-Dimer, INR, HbA1c and NT-proBNP\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eLumiraDX Rapid Test from Roche Diagnostics\u003c\/li\u003e\n\t\u003cli\u003eSpecifically designed for the LumiraDX PoC system\u003c\/li\u003e\n\t\u003cli\u003eQuick test procedure in just a few steps\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eDelivers reliable results within minutes\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eMinimal hands-on time saves valuable resources\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eEspecially simple sample collection\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eMatching quality control available\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eAvailable for various parameters\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eExcluded from return policy\u003c\/li\u003e\n\t\u003cli\u003eFor professional in-vitro diagnostics only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\n\u003cdiv class=\"c-text__table\"\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:1000px\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eCRP\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eD-Dimer\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eINR\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eHbA1c\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eNT-proBNP\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCapillary blood\u003cbr\u003e\n\t\t\tPlasma*\u003cbr\u003e\n\t\t\tWhole blood*\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCapillary blood\u003cbr\u003e\n\t\t\tPlasma**\u003cbr\u003e\n\t\t\tWhole blood**\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCapillary blood\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCapillary blood\u003cbr\u003e\n\t\t\tWhole blood***\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCapillary blood\u003cbr\u003e\n\t\t\tPlasma*\u003cbr\u003e\n\t\t\tWhole blood*\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eSample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20 μl\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15 μl\u003c\/td\u003e\n\t\t\t\u003ctd\u003e8 μl\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15 μl\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20 μl\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eTest Duration\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4 minutes\u003c\/td\u003e\n\t\t\t\u003ctd\u003e6 minutes\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026lt; 90 seconds\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5 minutes\u003c\/td\u003e\n\t\t\t\u003ctd\u003e12 minutes\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003ePrecision\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026lt; 10% CV\u003c\/td\u003e\n\t\t\t\u003ctd\u003e≤ 11.1% CV\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026lt; 3.73% CV\u003c\/td\u003e\n\t\t\t\u003ctd\u003e≤ 4% CV\u003c\/td\u003e\n\t\t\t\u003ctd\u003e≤ 12% CV\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5.0–250.0 mg\/l\u003c\/td\u003e\n\t\t\t\u003ctd\u003e190–4000 μg\/l FEU\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.8–80 INR\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20–130 mmol\/mol\u003c\/td\u003e\n\t\t\t\u003ctd\u003e50–9000 pg\/ml (ng\/l)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eHaematocrit\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15–55%\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20–55%\u003c\/td\u003e\n\t\t\t\u003ctd\u003e25–55%\u003c\/td\u003e\n\t\t\t\u003ctd\u003e6–21 g\/dl\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15–55%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eTransfer Tube\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLithium heparin\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLithium heparin\u003c\/td\u003e\n\t\t\t\u003ctd\u003eWithout anticoagulant\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003eLithium heparin\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2–30 °C\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2–30 °C\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5–32 °C\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2–30 °C\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2–30 °C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eContents\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e24 tests\u003c\/td\u003e\n\t\t\t\u003ctd\u003e12 tests\u003c\/td\u003e\n\t\t\t\u003ctd\u003e48 tests\u003c\/td\u003e\n\t\t\t\u003ctd\u003e24 tests\u003c\/td\u003e\n\t\t\t\u003ctd\u003e12 tests\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp\u003e*Lithium heparin\u003cbr\u003e\n**Sodium citrate\u003cbr\u003e\n***EDTA\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eIntended Use and Clinical Benefits\u003c\/h3\u003e\n\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eCRP\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\n\u003cp\u003eCRP tests at the point of care enhance diagnostic confidence and support the decision for the \u003cstrong\u003etargeted use of antibiotics in primary care.\u003c\/strong\u003e Using the CRP test can help \u003cstrong\u003ereduce antibiotic consumption\u003c\/strong\u003e without compromising patient recovery.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eD-Dimer\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe LumiraDx D-Dimer Test can be used in combination with a clinical pre-test probability assessment model to \u003cstrong\u003erule out deep vein thrombosis (DVT) or pulmonary embolism (PE)\u003c\/strong\u003e in symptomatic patients.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eINR\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe LumiraDx INR Test determines the \u003cstrong\u003equantitative prothrombin time,\u003c\/strong\u003e expressed as the International Normalised Ratio (INR), from a single capillary blood sample taken from the fingertip. When performed in a clinic or at home by trained medical staff, the results are available rapidly, allowing the \u003cstrong\u003etreatment plan to be adjusted immediately\u003c\/strong\u003e – without the need for an additional appointment or venous blood draw.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eHbA1c\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe LumiraDx HbA1c Test is suitable both for the \u003cstrong\u003elong-term monitoring of blood glucose levels\u003c\/strong\u003e in individuals with diabetes and to \u003cstrong\u003esupport screening for assessing diabetes risk.\u003c\/strong\u003e The ability to measure HbA1c provides valuable insights for clinical decision-making regarding appropriate treatment intensification.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eNT-proBNP\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe LumiraDx NT-proBNP Test supports the \u003cstrong\u003ediagnosis of heart failure in symptomatic patients.\u003c\/strong\u003e In combination with clinical assessment, ruling out heart failure in primary care can help avoid unnecessary specialist referrals and identify those who require further diagnostic evaluation.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Orange Medical","offers":[{"title":"HbA1c","offer_id":51901343105351,"sku":"150353","price":56.24,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/6301\/9079\/files\/150348-lumiradx-schnelltest-roche-inr-verpackungsinhalt_64c0fcdb-6e1c-4ac9-bc7c-daa15794139c.jpg?v=1752137625","url":"https:\/\/orangemedical.co.uk\/products\/lumiradx-rapid-test-hba1c","provider":"Orange Medical","version":"1.0","type":"link"}