{"product_id":"libero-w-set","title":"LIBERO W Set","description":"\u003cspan class=\"c-text__label\"\u003eProduct overview\u003c\/span\u003e\n \u003cul class=\"c-text__list\"\u003e\n \u003cli\u003eWireless PDF data logger with internal NTC sensor\n\u003c\/li\u003e\n \u003cli\u003eTemperature range: -35 °C to +50 °C\n\u003c\/li\u003e\n \u003cli\u003eSimple set-up in under 10 minutes\n\u003c\/li\u003e\n \u003cli\u003eAutomatic PDF report generation (min\/max lists)\n\u003c\/li\u003e\n \u003cli\u003eAcoustic and visual alarms in the event of deviations\u003c\/li\u003e\n \u003c\/ul\u003e \u003ch4\u003eLIBERO W Set\u003c\/h4\u003e\n\n\u003cp\u003eThe LIBERO W Set from Elpro provides a reliable and efficient solution for monitoring temperatures in demanding environments such as \u003cstrong\u003epharmacies, laboratories, clinics\u003c\/strong\u003e and \u003cstrong\u003etransport logistics\u003c\/strong\u003e. The device is specifically designed to safely monitor sensitive \u003cstrong\u003emedications, laboratory samples\u003c\/strong\u003e and other temperature-sensitive materials.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVisual and audible alarm functions \u003c\/strong\u003eimmediately signal if \u003cstrong\u003etemperature thresholds\u003c\/strong\u003e are exceeded. The \u003cstrong\u003esetup\u003c\/strong\u003e is incredibly simple and takes \u003cstrong\u003eless than ten minutes\u003c\/strong\u003e, making it quick and easy to start monitoring. As the system is \u003cstrong\u003ebattery-operated\u003c\/strong\u003e, \u003cstrong\u003eno internet connection\u003c\/strong\u003e or \u003cstrong\u003enetwork connection\u003c\/strong\u003e is required.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe LIBERO W Set automatically generates daily \u003cstrong\u003ePDF reports\u003c\/strong\u003e containing embedded measurement data as well as \u003cstrong\u003emin\/max records\u003c\/strong\u003e and is fully \u003cstrong\u003eGxP-compliant\u003c\/strong\u003e, including \u003cstrong\u003eFDA 21 CFR Part 11\u003c\/strong\u003e. With \u003cstrong\u003eGAMP 5 validation\u003c\/strong\u003e, it is ideal for use in regulated environments. Additionally, the \u003cstrong\u003ebatteries\u003c\/strong\u003e are easily replaceable, with \u003cstrong\u003elithium batteries recommended for freezer applications\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eLIBERO W Set from Elpro\u003c\/li\u003e\n\t\u003cli\u003eIdeal for pharmacies, laboratories, clinics and transport logistics\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eTemperature range of -35 °C to +50 °C\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eVisual and audible alarms for threshold breaches\u003c\/li\u003e\n\t\u003cli\u003eSimple setup in less than 10 minutes\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eBattery-operated, no internet or network connection required\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eAutomatic generation of PDF reports with embedded measurement data\u003c\/li\u003e\n\t\u003cli\u003eMin\/max temperature records in daily PDF reports\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eFully GxP-compliant and FDA 21 CFR Part 11 compliant\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eGAMP 5 validated for secure operation in regulated environments\u003c\/li\u003e\n\t\u003cli\u003eReplaceable alkaline batteries (lithium batteries recommended for freezer applications)\u003c\/li\u003e\n\t\u003cli\u003eFree calibration certificate and software (elproVIEWER, freeCONFIG)\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eWHO registered: E006\/056\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003eIncluded: Base station with internal NTC sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMeasurement range (sensor): -35 °C to +50 °C\u003c\/li\u003e\n\t\u003cli\u003eMeasurement accuracy: ±0.1 °C (at -35 °C to -10.1 °C), ±0.5 °C (at -10 °C to -0.1 °C)\u003c\/li\u003e\n\t\u003cli\u003eBattery: Replaceable AAA alkaline batteries (lithium for freezing applications)\u003c\/li\u003e\n\t\u003cli\u003eCertificates: ISO 17025 calibration, NIST\/UKAS certified\u003c\/li\u003e\n\t\u003cli\u003eDisplay: LCD, 32 × 80 mm, multifunction display\u003c\/li\u003e\n\t\u003cli\u003eOperating time: Up to 2 years at a measurement interval of 15 minutes\u003c\/li\u003e\n\t\u003cli\u003eProtection class: IP 54\/NEMA 13 (base station), IP 67\/NEMA 6 (sensor)\u003c\/li\u003e\n\t\u003cli\u003eCompliance: CE, FCC, ISO 19005-1\u003c\/li\u003e\n\t\u003cli\u003eDimensions: 115 x 82.5 x 27 mm\u003c\/li\u003e\n\t\u003cli\u003eWeight: 195 g\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Orange Medical","offers":[{"title":"Default Title","offer_id":51902373560647,"sku":"149816","price":427.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/6301\/9079\/files\/149816-libero-w-station-elpro_74c976c1-af2a-4920-be82-e86010a1d684.jpg?v=1752167643","url":"https:\/\/orangemedical.co.uk\/products\/libero-w-set","provider":"Orange Medical","version":"1.0","type":"link"}